Meet Our Acrylic TubUpdated 6 days ago
Product Overview
The Acrylic Tub is where precision meets permanence. Built from high-gloss acrylic with an ergonomic reclined shape, it's designed to fit seamlessly into home, clinic, or studio spaces while delivering a genuinely comfortable full-body plunge. Paired with a quiet 0.6 HP chiller, it's engineered for daily use.
Specs at a Glance
A rigid, freestanding cold plunge designed for permanent installation and daily use.
| Acrylic Tub Bundle | |
|---|---|
| Availability | AU + US only |
| Capacity | Solo (1 person) |
| Fill Volume | ~90–105 gal (~341–398L) |
| Bath Volume | ~145 gal (~549L) |
| Net Weight (Tub) | ~100–110 lbs (~45–50 kg) |
| Net Weight (Chiller) | ~80.25 lbs (~37 kg) |
| Horsepower | 2/3 HP (0.667 HP) |
| Input Power | ~810W |
| Cooling Capacity | ~1,420W |
| Heating Capacity | ~2,200W |
| Water Temp Range | 36–108°F (2–42°C) |
| Water Filter | Dual filtration. Ozone sanitation. |
| Construction | High-quality acrylic shell with insulated reinforcement. |
| Dimensions (Tub) | 66" × 31" × 28" |
| Dimensions (Chiller) | 22" × 13" × 17" |
| Wi-Fi Enabled | Tuya Smart App |
| Chiller | Acrylic Chiller 0.6HP—bundle only, not available separately. |
| Use | Indoor and outdoor use. |
| Setup | Permanent installation, curbside delivery. |
| Running Cost | ~$0.50/day |
| Warranty | 12 months |
| Certifications | CE, RoHS, IPX4, ISO |
In the Box
Acrylic Tub
- Acrylic Tub
- Oxford Cloth Insulation Lid
- Spare Parts Kit
Acrylic 0.6HP Chiller
- Chiller Unit with integrated sediment filter and paper filter housing
- Paper filter cartridge
- 2x hoses
- Repair kit
Setup
The Acrylic Tub is a permanent or semi-permanent installation.
- Choose your final position before filling. The tub is very heavy once full and should not be moved.
- Ensure drain access is available below or beside the tub.
- Place the chiller on a stable, level surface nearby with ~100 cm clearance around the vents.
- Leave the chiller upright for 24 hours after delivery before powering on for the first time.
- Confirm the drain valve is fully closed before filling.
- Connect the chiller hoses to the IN and OUT fittings before adding water. Make sure all valves are hand-tight.
- Fill to 5–7 cm below the rim. Open the drainer briefly to purge any air, then close it once the flow stabilises.
- Power on, confirm water flow is above 14 L/min on the control panel, and set your target temperature via the Tuya Smart App.
Your user manual covers full installation steps. If you need a hand, contact us.
Your First Session
The Acrylic Tub cools and heats, so it works year-round.
Before you get in
- Set your target temperature via the Tuya Smart App and allow time to cool.
- Starting temperature and water volume will affect how long it takes to reach your target.
- A good starting point is 55–60°F (13–15°C). You don't need to go straight to the minimum.
- The benefits are well established at moderate cold temperatures.
- The ergonomic recline is intentional. Let your body settle into the shape rather than sitting upright. It makes a noticeable difference to comfort, especially in longer sessions.
In the water
- Aim for 2–3 minutes for your first session. Build to 5–10 minutes over time as your body adapts.
- Slow, controlled breathing is more effective than trying to push through the cold.
- A few slow exhales in the first 30 seconds will help your nervous system settle.
- Keep hands submerged where possible. You lose significant heat through your hands and keeping them in makes sessions more effective.
After your session
- Let your body rewarm naturally before jumping into a hot shower. The rewarming process is part of where the metabolic benefit happens.
- If you have a SaunaPod or XEN, contrast therapy (alternating heat and cold) is one of the most effective recovery protocols you can build at home.
A note on the ozone cycle
- The chiller runs an automatic ozone sterilisation cycle to keep the water clean.
- You can adjust the settings via the app.
- Do not use bleach or corrosive disinfectants in the water. The ozone system handles sanitisation.
Care & Maintenance
The Acrylic Tub is low-maintenance by design. Simple habits keep it performing well long-term.
The tub
- Clean with mild, non-abrasive cleaners only.
- No bleach, abrasives or solvents. They'll permanently damage the acrylic surface.
- For mineral buildup: diluted white vinegar (1:4 with water) on a soft cloth, rinse thoroughly.
- Dry the interior between uses where possible to prevent biofilm buildup.
- Leave the lid slightly open between uses to allow air circulation.
The chiller
- Clean the built-in mesh filter monthly. Rinse it and reinstall it.
- Replace the paper filter every 4–6 weeks, depending on use. Always switch the RCD off before replacing the paper filter.
- Clean the dust net on the chiller every 3 months.
- Keep ~100 cm clearance around the chiller vents at all times.
- Inspect hose connections and fittings quarterly for wear, looseness, or leaks.
- Do not power on the chiller while anyone is in the water.
Winter and extended storage
If temperatures are expected to drop below 32°F (0°C), or the tub will be unused for 4 or more weeks:
- Turn off and disconnect the chiller.
- Open the drain valve and attach a hose to direct water to a suitable drain point.
- Open the drainer on the chiller to fully drain all water from the unit and connected piping.
- Store the chiller indoors if possible. Freezing temperatures will permanently damage internal components.
- Leave the drain valve open during storage.