Meet Our Acrylic TubUpdated 6 days ago

Product Overview

The Acrylic Tub is where precision meets permanence. Built from high-gloss acrylic with an ergonomic reclined shape, it's designed to fit seamlessly into home, clinic, or studio spaces while delivering a genuinely comfortable full-body plunge. Paired with a quiet 0.6 HP chiller, it's engineered for daily use.


Specs at a Glance

A rigid, freestanding cold plunge designed for permanent installation and daily use.


Acrylic Tub Bundle
AvailabilityAU + US only
CapacitySolo (1 person)
Fill Volume~90–105 gal (~341–398L)
Bath Volume~145 gal (~549L)
Net Weight (Tub)~100–110 lbs (~45–50 kg)
Net Weight (Chiller)~80.25 lbs (~37 kg)
Horsepower2/3 HP (0.667 HP)
Input Power~810W
Cooling Capacity~1,420W
Heating Capacity~2,200W
Water Temp Range36–108°F (2–42°C)
Water FilterDual filtration. Ozone sanitation.
ConstructionHigh-quality acrylic shell with insulated reinforcement.
Dimensions (Tub)66" × 31" × 28"
Dimensions (Chiller)22" × 13" × 17"
Wi-Fi EnabledTuya Smart App
ChillerAcrylic Chiller 0.6HP—bundle only, not available separately.
UseIndoor and outdoor use.
SetupPermanent installation, curbside delivery.
Running Cost~$0.50/day
Warranty12 months
CertificationsCE, RoHS, IPX4, ISO

In the Box

Acrylic Tub

  • Acrylic Tub
  • Oxford Cloth Insulation Lid
  • Spare Parts Kit

Acrylic 0.6HP Chiller

  • Chiller Unit with integrated sediment filter and paper filter housing
  • Paper filter cartridge
  • 2x hoses
  • Repair kit

Setup

The Acrylic Tub is a permanent or semi-permanent installation.

  1. Choose your final position before filling. The tub is very heavy once full and should not be moved.
  2. Ensure drain access is available below or beside the tub.
  3. Place the chiller on a stable, level surface nearby with ~100 cm clearance around the vents.
  4. Leave the chiller upright for 24 hours after delivery before powering on for the first time.
  5. Confirm the drain valve is fully closed before filling.
  6. Connect the chiller hoses to the IN and OUT fittings before adding water. Make sure all valves are hand-tight.
  7. Fill to 5–7 cm below the rim. Open the drainer briefly to purge any air, then close it once the flow stabilises.
  8. Power on, confirm water flow is above 14 L/min on the control panel, and set your target temperature via the Tuya Smart App.

Your user manual covers full installation steps. If you need a hand, contact us.


Your First Session

The Acrylic Tub cools and heats, so it works year-round.

Before you get in

  • Set your target temperature via the Tuya Smart App and allow time to cool. 
  • Starting temperature and water volume will affect how long it takes to reach your target.
  • A good starting point is 55–60°F (13–15°C). You don't need to go straight to the minimum.
  • The benefits are well established at moderate cold temperatures.
  • The ergonomic recline is intentional. Let your body settle into the shape rather than sitting upright. It makes a noticeable difference to comfort, especially in longer sessions.

In the water

  • Aim for 2–3 minutes for your first session. Build to 5–10 minutes over time as your body adapts.
  • Slow, controlled breathing is more effective than trying to push through the cold. 
  • A few slow exhales in the first 30 seconds will help your nervous system settle.
  • Keep hands submerged where possible. You lose significant heat through your hands and keeping them in makes sessions more effective.

After your session

  • Let your body rewarm naturally before jumping into a hot shower. The rewarming process is part of where the metabolic benefit happens.
  • If you have a SaunaPod or XEN, contrast therapy (alternating heat and cold) is one of the most effective recovery protocols you can build at home.

A note on the ozone cycle

  • The chiller runs an automatic ozone sterilisation cycle to keep the water clean. 
  • You can adjust the settings via the app. 
  • Do not use bleach or corrosive disinfectants in the water. The ozone system handles sanitisation.

Care & Maintenance

The Acrylic Tub is low-maintenance by design. Simple habits keep it performing well long-term.

The tub

  • Clean with mild, non-abrasive cleaners only.
  • No bleach, abrasives or solvents. They'll permanently damage the acrylic surface.
  • For mineral buildup: diluted white vinegar (1:4 with water) on a soft cloth, rinse thoroughly.
  • Dry the interior between uses where possible to prevent biofilm buildup.
  • Leave the lid slightly open between uses to allow air circulation.

The chiller

  • Clean the built-in mesh filter monthly. Rinse it and reinstall it.
  • Replace the paper filter every 4–6 weeks, depending on use. Always switch the RCD off before replacing the paper filter.
  • Clean the dust net on the chiller every 3 months.
  • Keep ~100 cm clearance around the chiller vents at all times.
  • Inspect hose connections and fittings quarterly for wear, looseness, or leaks.
  • Do not power on the chiller while anyone is in the water.

Winter and extended storage

If temperatures are expected to drop below 32°F (0°C), or the tub will be unused for 4 or more weeks:

  1. Turn off and disconnect the chiller.
  2. Open the drain valve and attach a hose to direct water to a suitable drain point.
  3. Open the drainer on the chiller to fully drain all water from the unit and connected piping.
  4. Store the chiller indoors if possible. Freezing temperatures will permanently damage internal components.
  5. Leave the drain valve open during storage.